Details
Environmental data monitoring and electrical security alarm systems AD2000
Description of environmental data monitoring and electrical security alarm systems:
Environmental data monitoring and electrical security alarm systems AD2000 integrates functions of enviroment & data monitoring and fire& burglar alarming, remote control. It can be applied to the fields of electric power, communications , petroleum, chemical industry to do the works of data control, fire alarm and burglar alarm.
Functions of environmental data monitoring and electrical security alarm systems:
GSM 900/1800/1900MHZ moudel (850/900/1800/1900MHZ available);
Can set 1 to 4 telephone numbers to receive alarm message;
Can set 1 to 2 telephone numbers to realize the voice dialing burglar alarm;
Four-channel AC voltage, DC voltage, temperature, standard DC 0-20mA analog data acquisition and alarm values;
Two relay controller output;
Two inputs (wired zones);
A wireless emergency call zone;
A wireless fire zone;
6 wireless alarm zones;
The working power failure alarm;
Main unit anti-disconnection alarm;
Wireless digital keypad programming or SMS programming;
Field monitor (standard);
Remote two-way intercom (optional);
Built-in user-recording function.
Specifications of environmental data monitoring and electrical security alarm systems:
1. Frequency module: GSM 900/1800/1900MHZ (standard); 850/900/1800/1900MHZ(optional)
2. Wireless accessories frequency: 315MHZ (standard),433 MHZ (optional);
3. Current: input-AC220/110V , 50/60 HZ;
output-DC15V/2A
4. Backup battery: lead-acid battery(rated voltage:12V;max voltage 13.8V, capability1200mAH)
5. Power consumption:0.9W
6. AC voltage input channel:
input range-0-300V,50HZ(standard)60HZ(optional);
withstand voltage: 2500VDC(current 1mA/1M)
Precision: ±1%
7. DC voltage input channel:
input range:0-60V;
withstand voltage: 2500VDC(current 1mA/1M)
Precision: ±1%
8. Temperature collecting channel:
measure range: -10-+60°C
sensor: -55-+150°C
Precision: ±1%
9. DC current input channel:
input range: 0-20mA;
Precision: ±1%,
can be connect with sensor with current of 4-20mA
10.With contant open and close connection joint.
11.Relay control the output with constant contact(7A/240VAC,10A/120VAC;
10A/28VDC);
12. User recording time: ≤ 8Senconds;
13. Voice start: 8ohm,0.25W;
14: Alarm drive:DC9-15V,120mA;
15. Size: 29cm X 25.5cm X 8.1cm,weight 2.8KG;
16.Storage temperature: -40-+85°C;
17.Working temperature:-10-+60°C;
18 Installation: wall-mounting in room
Additional Information
| Memory | No |
|---|